Vue de la page 0
1
1.00 INTRODUCTION . . . . . . . . . . . . . . . 2
2.00 DTMB OVERVIEW . . . . . . . . . . . . . 3
3.00 DESCRIPTION OF KEYS . . . . . . . . . 4
4.00 QUICK START INSTRUCTIONS . . 5
4.10 Setup
4.20 Operation
5.00 SETUP . . . . . . . . . . . . . . . . . . . . . . 8
5.10 Installing Batteries
5.20 AC Adapter
5.30 Configuring Dip Switches
5.31 Access the DIP Switch Block
5.32 Setting the DIP Switches . . . .
5.40 Thickness Compensator
5.41 Preparing Sample .
5.42 Inserting Sample .
5.50 Gravity Correction (Zero)
6.00 BUILT-IN MEMORY SYSTEM . . . . 14
6.10 Standard Memory
6.11 Viewing Data
6.12 Clearing Data
6.20 Standard NAPO Memory
7.00 CALIBRATION . . . . . . . . . . . . . . . . 16
7.10 Checking Calibration
7.20 Field Calibration Adjustment
7.30 Special Calibraton
8.00 GENERAL NOTES . . . . . . . . . . . . . 19
8.10 Turning Power On/OFF
8.20 Display Indicators & Codes
8.21 Over Range
8.22 EPROM Error
8.23 Low Battery
8.30 Options
8.31 Ultra-High Speed Rollers
8.32 Lever
8.33 AC Adapter
8.34 Special Calibration
8.40 On-Line Mounting Holes
9.00 SPECIFICATIONS . . . . . . . . . . . . . . 22
10.00 WARRANTY . . . . . . . . . . . . . . . . . . 24
INDEX
OI810B
24
10.00 WARRANTY
ELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to the original pur-
chaser that this product is of merchantable quality and confirms in kind and quality with
the descriptions and specifications thereof. Product failure or malfunction arising out of
any defect in workmanship or material in the product existing at the time of delivery
thereof which manifests itself within one year from the sale of such product, shall be
remedied by repair or replacement of such product, at ELECTROMATIC’s option, except
where unauthorized repair, disassembly, tampering, abuse or misapplications has taken
place, as determined by ELECTROMATIC. All returns for warranty or non-warranty
repairs and/or replacement must be authorized by ELECTROMATIC, in advance, with all
repacking and shipping expenses to the address below to be borne by the purchaser.
THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, THE WARRANTY
OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE OR
APPLICATION. ELECTROMATIC SHALL NOT BE RESPONSIBLE NOR LIABLE FOR
ANY CONSEQUENTIAL DAMAGE, OF ANY KIND OR NATURE, RESULTING FROM
THE USE OF SUPPLIED EQUIPMENT, WHETHER SUCH DAMAGE OCCURS OR IS
DISCOVERED BEFORE, UPON OR AFTER REPLACEMENT OR REPAIR, AND
WHETHER OR NOT SUCH DAMAGE IS CAUSED BY MANUFACTURER’S OR
SUPPLIER’S NEGLIGENCE WITHIN ONE YEAR FROM INVOICE DATE.
Some State jurisdictions or States do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation may not apply to you. The duration of any
implied warranty, including, without limitation, fitness for any particular purpose and
merchantability with respect to this product, is limited to the duration of the foregoing
warranty. Some states do not allow limitations on how long an implied warranty lasts
but, not withstanding, this warranty, in the absence of such limitations, shall extend for
one year from the date of invoice.
ELECTROMACTIC Equipment Co., Inc.
600 Oakland Ave. Cedarhurst, NY 11516—USA
Tel: 1-800-645-4330/ Tel: 516-295-4300/ Fax: 516-295-4399
Vue de la page 0
1 2 3 4 5 6 ... 12 13

Résumé du contenu

Page 1 - 10.00 WARRANTY

11.00 INTRODUCTION . . . . . . . . . . . . . . . 22.00 DTMB OVERVIEW . . . . . . . . . . . . . 33.00 DESCRIPTION OF KEYS . . . . . . . . . 44.00 QU

Page 2 - Specifications

105.30 Configuring Dip SwitchesThe DTMB is supplied with six (6) dip switches permitting the user to selectdesired Display Update Rate and Memory Mode

Page 3 - 10.00 SPECIFICATIONS

114. The Dip Switch Block will be located at the top of the opening after removing the Slide Guide Plate.5.32 Setting Dip SwitchesUsing a small slotte

Page 4

13125.42 Inserting Sample Into Thickness CompensatorPush the Thumbpiece forward to separate the twoanvils. Insert the sample into the slot and slowlyr

Page 5 - Correction procedure (Zero):

ELECTROMATIC E Q U I P M E N T C O., I N C.600 Oakland Ave., Cedarhurst, NY 11516–U.S.A.TEL: 516-295-4300 • FAX: 516-295-4399 CHECK•LINE®INSTRUMENTSO

Page 6 - Thumbpiece

21.00 INTRODUCTIONThe CHECK•LINE®DTMB Digital Tension Meter is a hand-held device whichaccurately measures the running as well as static tensions of a

Page 7 - 5 seconds

3Filament GuideRollersLCD DisplaySlide Guide PlateThickness Compensator(on back of unit)Field CalibrationAdjustmentSTORE KeyRecall KeyPower/Exit KeyMi

Page 8 - 7.10 Checking Calibration

4• Starts/Stops scanning for Max/Min/Peak values. (Standard Memory)• Starts/Stops automatic recording of values into memory (Continuous Data Logging

Page 9 - 7.00 CALIBRATION

54.00 QUICK START INSTRUCTIONS4.10 Setup1. Insert a sample of the process material into the Thickness Compensator and secure the ends of the sample un

Page 10 - ECALL key Last Reading none

63. Open the 3-roller system by pushing the Thumbpiece forward until the outer rollersextend beyond the Filament Guide. Position the DTMB so that the

Page 11

76. Press the key repeatedly to review the data stored in memory.Press the key at any time to exit Recall Mode.The DTMB will automat

Page 12 - 1-1/2"

85.00 SETUP5.10 Installing/Replacing Batteries1. Using a slotted screwdriver or coin, loosen the battery cover screw located at the end of the unit by

Page 13 - TENSION METER

95.20 Using AC-AdapterThe optional AC-DTMX AC Adapter can beused as an alternative to batteries. Plug oneend of the adapter into an appropriate ACoutl