11.00 WARRANTY
ELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to the original pur-
chaser that this product is of merchantable quality and confirms in kind and quality
with the descriptions and specifications thereof. Product failure or malfunction arising
out of any defect in workmanship or material in the product existing at the time of deliv-
ery thereof which manifests itself within one year from the sale of such product, shall be
remedied by repair or replacement of such product, at ELECTROMATIC’s option, except
where unauthorized repair, disassembly, tampering, abuse or misapplication has taken
place, as determined by ELECTROMATIC. All returns for warranty or non-warranty
repairs and/or replacement must be authorized by ELECTROMATIC, in advance, with
all repacking and shipping expenses to the address below to be borne by the purchaser.
THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, THE WARRANTY
OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE OR
APPLICATION. ELECTROMATIC SHALL NOT BE RESPONSIBLE NOR LIABLE
FOR ANY CONSEQUENTIAL DAMAGE, OF ANY KIND OR NATURE, RESULTING
FROM THE USE OF SUPPLIED EQUIPMENT, WHETHER SUCH DAMAGE OCCURS
OR IS DISCOVERED BEFORE, UPON OR AFTER REPLACEMENT OR REPAIR, AND
WHETHER OR NOT SUCH DAMAGE IS CAUSED BY MANUFACTURER’S OR SUP-
PLIER’S NEGLIGENCE WITHIN ONE YEAR FROM INVOICE DATE.
Some State jurisdictions or States do not allow the exclusion or limitation of incidental
or consequential damages, so the above limitation may not apply to you. The duration
of any implied warranty, including, without limitation, fitness for any particular purpose
and merchantability with respect to this product, is limited to the duration of the forego-
ing warranty. Some states do not allow limitations on how long an implied warranty
lasts but, not withstanding, this warranty, in the absence of such limitations, shall
extend for one year from the date of invoice.
ELECTROMATIC Equipment Co., Inc.
600 Oakland Ave. Cedarhurst, NY 11516—USA
Tel: 1-800-645-4330/ Tel: 516-295-4300/ Fax: 516-295-4399
1.00 INTRODUCTION . . . . . . . . . . . . . 2
2.00 DTMX OVERVIEW . . . . . . . . . . . . 3
3.00 DESCRIPTION OF KEYS . . . . . . 4
3.10 Auxiliary Functions
4.00 QUICK START INSTRUCTIONS . 5
4.10 Setup
4.20 Operation
5.00 SETUP . . . . . . . . . . . . . . . . . . . . 8
5.10 Installing Batteries
5.20 AC Adapter
5.30 Configuring Dip Switches
5.31 Access the DIP Switch Block
5.32 Setting the DIP Switches . .
5.40 Material Rigidity Selector
5.50 Thickness Compensator
5.51 Preparing Sample
5.52 Inserting Sample
5.60 Gravity Correction (Zero)
6.00 BUILT-IN MEMORY SYSTEM . . . 14
6.10 Standard Memory
6.11 Viewing Data
6.12 Clearing Data
6.20 Standard NAPO Memory
6.30 On-Demand Data Logging
6.31 Viewing Data
6.32 Clearing data
6.40 Continuous Data Logging
6.41 Viewing Data
6.42 Clearing Data
7.00 DOWNLOADING DATA . . . . . . . 19
7.10 Output Cables
7.20 Connector Pinouts
7.30 Analog Output
7.40 Serial Output - Printer
7.41 Signal Characteristics
7.42 Printer Setup Data
7.50 Serial Output - Computer
7.51 Signal Characteristics
7.52 Data Format
8.00 CALIBRATION . . . . . . . . . . . . . . 23
8.10 Checking Calibration
8.20 Field Calibration Adjustment
8.30 Special Calibration
9.00 GENERAL NOTES . . . . . . . . . . . 26
9.10 Turning Power On/OFF
9.20 Display Indicators & Error
Codes . . . . . . . . . . . . . . . . . . . .
9.21 Over Range Indicator
9.22 Error Codes .
9.23 Low Battery
9.30 Standard Dev. & Avg. Formulas
9.40 Changing Units of Measure
9.50 Options
9.51 Ultra-High Speed Rollers . .
9.52 Lever
9.53 Printer
9.54 Serial Output Cable
9.55 Analog Output Cable . .
9.56 AC Adapter
9.57 Special Calibration
9.60 On-Line Mounting Holes
10.00 SPECIFICATIONS . . . . . . . . . . . . 30
11.00 WARRANTY . . . . . . . . . . . . . . . . 32
INDEX
OI808X
Vue de la page 0
1 2 3 4 5 6 ... 16 17

Résumé du contenu

Page 1 - 11.00 WARRANTY

32 111.00 WARRANTYELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to the original pur-chaser that this product is of merchantable quality and

Page 2 - Specifications

105.30 Configuring Dip SwitchesThe DTMX is supplied with six (6) dip switches permitting the user to selectdesired Display Update Rate, Memory Mode an

Page 3 - 10.00 SPECIFICATIONS

114. The Dip Switch Block will be located at the top of the opening after removing the Slide Guide Plate.5.32 Setting Dip SwitchesUsing a small slotte

Page 4

5.40 Material Rigidity SelectorThe Material Rigidity Selector permits the user to set theDTMX for use on Textiles or Wires. It is used in the com-pute

Page 5 - Correction procedure (Zero):

5.51 Preparing Sample For Thickness CompensatorWhen using monofilament, wire or other difficult-to-bend materials, the sample must be preparedproperly

Page 6 - Thumbpiece

146.00 BUILT-IN MEMORY SYSTEMThe DTMX Built-In Memory system can be configured to operate in one of thefollowing modes: Standard Memory, Standard Memo

Page 7 - 5 seconds

6.11 Viewing Data In Standard MemoryTo view data stored in Standard Memory, press the key.The following will be displayed when the key is pressed re

Page 8

6.30 On-Demand Data Logging ModeWhen configured for On-Demand Data Logging Mode, up to 100 data pointscan be stored in memory along with the calculate

Page 9 - 8.10 Checking Calibration

OPERATING MANUALDigitalTENSION METERCHECK•LINE®BY ELECTROMATICModel DTMXELECTROMATIC E Q U I P M E N T C O., I N600 Oakland Ave., Cedarhurst, NY 1151

Page 10

31SpecificationsMeasuring Principle Strain gaugeMeasuring Frequency 16 msec (62.5 samples/sec) Deflection of Sensing Roller (max.) 0.2 mmOverload C

Page 11

3Filament GuideRollersLCD DisplaySlide Guide PlateThicknessCompensator (on back of unit)Field CalibrationAdjustmentSTORE KeyRecall KeyPower/Exit KeyD

Page 12 - TEX WIRE

9.55 Analog CableThe CA cable is for connection to chartrecorders or other recording devices. It is supplied with bare leads for easy connection to

Page 13 - Digimatic

4.00 QUICK START INSTRUCTIONS4.10 Setup1. Insert a sample of the process material into the Thickness Compensator andsecure the ends of the sample unde

Page 14 - Chart Recorder

9.23 Low BatteryWhen the “B” indicator appears on thedisplay, the batteries are low. If data isstored in memory, download it beforereplacing batteri

Page 15 - Minimum Value

6. Press the key repeatedly to review the data stored in memory.Press the key at any time to exit Recall Mode.The DTMX will automati

Page 16

8.20 Field Calibration AdjustmentThe Field Calibration Adjustment permitsthe end user to "shift" the calibration curveto provide better accu

Page 17 - TENSION METER

95.20 Using AC-AdapterThe optional AC-DTMX AC Adapter can beused as an alternative to batteries. Plug oneend of the AC-adapter into an appropriateAC o

Commentaires sur ces manuels