TABLE OF CONTENTS
01.0 Introduction ............................................................................................................. 0 02
02.0 Overview ................................................................................................................. 0 03
2.1 Operating Elements
2.2 Installing And Replacing The Battery
2.3 Turning The Power On and Off
2.4 Reversing The Display
2.5 Selecting The Unit Of Measure
2.6 Zero Adjustment of the Measuring Position
03.0 Removing and Re-Mounting The Filament Guide .................................................... 06
04.0 Taking A Measurement ............................................................................................. 07
4.1 Inserting The Process Material
4.2 Measuring
4.3 Removing The Process Material
05.0 Damping Mode .......................................................................................................... 08
5.1 Switching On The Damping Mode
5.2 Switching Off The Damping Mode
5.3 Changing the Damping Factor
06.0 Storing and Recalling Tension Values ....................................................................... 09
6.1 Storing Tension Values
6.2 Recalling Tension Values
6.3 Clearing Values Stored In Memory
6.4 Memory HOLD Function
6.5 Error Messages
07.0 Static Verication of Measuring Accuracy ................................................................ 12
08.0 Calibration ................................................................................................................. 13
8.1 Dynamic Calibration
8.2 Static Calibration
8.3 Error Messages
8.4 Restoring Factory Defaults
09.0 Specications ............................................................................................................ 17
10.0 Appendix - Replacing the Rollers / Ceramic Pins ...................................................... 18
11.0 Warranty .......................................................................................................................20
OI-1110
– 20 –
11.0 WARRANTY
ELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to the original
purchaser that this product is of merchantable quality and conrms in kind and quality
with the descriptions and specications thereof. Product failure or malfunction arising
out of any defect in workmanship or material in the product existing at the time of
delivery thereof which manifests itself within one year from the sale of such product,
shall be remedied by repair or replacement of such product, at ELECTROMATIC’s
option, except where unauthorized repair, disassembly, tampering, abuse or
misapplication has taken place, as determined by ELECTROMATIC. All returns
for warranty or non-warranty repairs and/or replacement must be authorized by
ELECTROMATIC, in advance, with all repacking and shipping expenses to the address
below to be borne by the purchaser.
THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, THE
WARRANTY OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR
PURPOSE OR APPLICATION. ELECTROMATIC SHALL NOT BE RESPONSIBLE
NOR LIABLE FOR ANY CONSEQUENTIAL DAMAGE, OF ANY KIND OR
NATURE, RESULTING FROM THE USE OF SUPPLIED EQUIPMENT, WHETHER
SUCH DAMAGE OCCURS OR IS DISCOVERED BEFORE, UPON OR AFTER
REPLACEMENT OR REPAIR, AND WHETHER OR NOT SUCH DAMAGE IS
CAUSED BY MANUFACTURER’S OR SUPPLIER’S NEGLIGENCE WITHIN ONE
YEAR FROM INVOICE DATE.
Some State jurisdictions or States do not allow the exclusion or limitation of incidental
or consequential damages, so the above limitation may not apply to you. The duration
of any implied warranty, including, without limitation, tness for any particular
purpose and merchantability with respect to this product, is limited to the duration of
the foregoing warranty. Some states do not allow limitations on how long an implied
warranty lasts but, not withstanding, this warranty, in the absence of such limitations,
shall extend for one year from the date of invoice.
ELECTROMATIC Equipment Co., Inc.
600 Oakland Ave. Cedarhurst, NY 11516—USA
Tel: 1-800-645-4330/ Tel: 516-295-4300/ Fax: 516-295-4399
Every precaution has been taken in the preparation of this manual. Electromatic
Equipment Co., Inc., assumes no responsibility for errors or omissions. Neither is any
liability assumed for damages resulting from the use of information contained herein.
Any brand or product names mentioned herein are used for identication purposes only,
and are trademarks or registered trademarks of their respective holders.
Vue de la page 0
1 2 3 4 5 6 ... 10 11

Résumé du contenu

Page 1 - 11.0 WARRANTY

– 1 –– 1 –TABLE OF CONTENTS01.0 Introduction ...

Page 2 - 1.0 INTRODUCTION

– 10 –6. Press the RECALL key. The display blinks, showing the maximum peak value of the measuring period and the indicated symbol.7. Press the

Page 3 - 2.0 OVERVIEW

CHECK•LINE® BY ELECTROMATIC Tension Meters ETMB-ETMPBOperating Manual ELECTROMATIC E Q U I P M E N T C O., I N C.600 Oakland Ave.

Page 4 - 9.0 SPECIFICATIONS

1.0 INTRODUCTIONThree long, closely-spaced slender shafts with precision guide rollers or pins at their ends combine with the latest in microprocess

Page 5 - D cN

– 3 –2.0 OVERVIEW2.1 Operating Elements6 DAMP key7 LEVER8 FILAMENT GUIDE9 USB output (for connecting the AC adapter1 ROLLERS or ceramic pins2

Page 6

– 4 –2.3 Turning the Power On and OffPower On: Press the POWER key until the DISPLAY momentarily shows the tension range and the software version, e

Page 7 - 4.0 TAKING A MEASUREMENT

– 5 –– 16 –8.3 Restoring Factory CalibrationYou can restore the factory calibration at any time with the following procedure:1. Switch off the tensi

Page 8 - 5.0 DAMPING MODE

– 6 –3.0 REMOVING AND REMOUNTING THE FILAMENT GUIDEThe tension meter is supplied with a FILAMENT GUIDE for fast and easy material acquisition. For app

Page 9

– 7 –4.0 TAKING A MEASUREMENTNOTE: Before taking a measurement, be sure that the correct unit of measurement (g or cN) has been selected and a

Page 10

– 8 –5.0 DAMPING MODEThe tension meter is equipped with an electronic damping that ensures steady readings when tension ucutates. This is achieved by

Page 11 - Tension Meters

– 9 –6.0 STORING AND RECALLING TENSION VALUESThe tension meter features a data logger which stores the followng data obtained during a measuring peri

Modèles reliés ETMB

Commentaires sur ces manuels

Pas de commentaire