DT-326
LED Stroboscope
Operation Manual
Read manual thoroughly prior to operation.
Use instrument only after reading the complete manual.
Follow all safety precautions.
Vue de la page 0
1 2 3 4 5 6 ... 34 35

Résumé du contenu

Page 1 - Operation Manual

DT-326 LED Stroboscope Operation Manual Read manual thoroughly prior to operation. Use instrument only after reading the complete manual.

Page 2 - Safety Precautions

7 3.3.5 Setting project display The following will be displayed, according to the mode of measure and *parameter settings

Page 3 - - Contents

8 4 Function Instructions 4.1 Power on/off Press “POWER” key to turn on unit. The unit will begin to flash in internal mode and the display will

Page 4

9 4.3 Internal flashing mode 4.3.1 Instruction for Internal flashing mode 4.3.2 Changing Units of Measure in Internal Mode Press and rel

Page 5 - Adapter (120V/240V, 50/60Hz)

10 4.3.4 Flash rate and frequency “Internal Mode” Set the flash rate (frequency) by turning the center dial. Clockwise: Increase

Page 6

11 4.3.5 Multiply / Divide by 2 Function The flash rate or frequency can be doubled or halved by the”x2” and “½” keys on the operation panel. 1) Do

Page 7 - LED light source (3 totals)

12 4.3.6 Phase Shift (Angle) Once "Frozen" virtual image is achieved via FPM=RPM, the phase shift function can advance or delay the flash

Page 8

13 Press the “RATIO” key. The current mode will start blinking for 5 seconds allowing modification at this point. Operation Indication ** Wh

Page 9

14 Operation Expression … … Auto Range Trigger Edge Deley Deg Flash Time Ave Last Min Max min sec hHz ○○○○ Auto Range Trigger

Page 10

15 4.4 External Trigger Mode This mode allows synchronization of the FPM with external signal input such as a sensor. See section 4.7 for details. P

Page 11

16 4.4.2.1 “Delay time” setting This can be set to 0~999 msec with a resolution of 1 ms. The internal calculation time of the unit is 60us, which

Page 12

Safety Precautions Please be sure to closely follow all safety precautions. Be sure to read the entire instruction manual thoroughly before initial s

Page 13 - 900 1 times 1

17 Press "PHASE+" key to select the delay time setting. Turn dial CW to increase and CCW to decrease. Button operation Expression

Page 14

18 4.4.2.2 “Delay angle” setting Set the delay angle from 0° to 360° in 1° increment s. The actual delay time is as follows: While the DT-326

Page 15

19 Delay Angle setting will decrease from 359° (Max) to 0° (Min) value for counter clockwise. The setting s will eventually go to 0°as when angle dec

Page 16

20 4.5 Parameter Setting Instruction Press “MODE” until the LCD displays “P” (Parameter setting mode). Press the “SET” key to cycle between the vari

Page 17

21 4.5.1 Measurement range setting The DT-326 has a selectable measuring range, which can be set in the Parameter mode setting. The range and res

Page 18

22 Operation Expression Measuring range set to “1 – 200 Hz” Auto Range Trigger Edge Deley Deg Flash Time Ave Last Min Max min sec

Page 19 - LED Flash

23 4.5.2 Trigger Edge setting (External Mode) Select Positive or Negative edge. Examples: -When trigger edge setting is set to “Positive Edge”, the

Page 20

24 Press the “SET” key to cycle to the Trigger Edge setting parameter mode. To set the trigger edge as “Down edge”, press “PHASE -“key or turn the di

Page 21

25 4.5.3 Delay setting Delay time and angle setting will allow the flash to be delayed after an external pulse is sensed by the unit. The Paramete

Page 22

26 4.5.3.2 Delay angle setting The delay angle can be set from 0° to 360° by 1° in crements. Delay angle setting increases as the dial turns right,

Page 23

- Contents - 1 Summary ...

Page 24 - (range 1.00 - 2000.0)

27 4.5.4 Back light setting Press “SET” key in Parameter mode to enable this mode. Turning off the backlight will conserve battery power. For mor

Page 25

28 4.7 Connector of External input/output 4.7.1 Connector specs and pin type Pin No Single name Remarks 1 +12V +12V power supply output 2 G

Page 26 - Trigger

29 4.7.4 Option Cable- Input/ Output cable adaptor Because the connector of the unit is not separate from input and output signal, the option cable

Page 27

30 5 Specifications Model Number DT-326 Units of measure FPM (flashes per minute) or Hz (frequency) Measuring range 1 - 2,000Hz 60 - 120,000 FPM

Page 28

31 Display LCD 6 digits (main), 5 digits (sub) “LOW BAT”, “Setting item”, “Unit” Back light Yellow green LED Flashing part Flash Source Super Hi

Page 29

32 6 Dimensions 1/4-20UNF Depth 8mm (0.32”) (2.05”) 52mm (1.42”) 36mm (0.12”)3mm(2.76”) (2.36”) 70mm 60mm (5.95”) 151mm (2

Page 30 - 4.6 Power-saving settings

1 1 Summary The DT-326 LED Stroboscope is a portable, AC/DC powered precision instrument used to illuminate and measure the rotational speeds of obj

Page 31

2 2 Product Inspection and Preparation 2.1 Confirmation of product packaging Confirm the following five parts in your DT-326 packaging:

Page 32 - Output (Other device)

3 2.2 Removal of protective sheet Remove both protective sheets covering the operation panel and light source as shown below. 2.3 In

Page 33 - 5 Specifications

4 3 Names and functions of the components 3.1 DT-326 Unit Flash rate/frequency setting dial Operation keys (9 totals) LCD

Page 34

5 3.2 Operation panel No. Key Function Instructions 1 POWER Power the unit on or off 2 MODE Select Internal/ External/ P

Page 35

6 3.3 LCD Display 3.3.1 Display Names and Descriptions 3.3.2 Main data display - Internal flashing mode: Displays flash rate. - Ex